MRF // COMMUNICATIONS

What MRF talks to, and how.

A fleet manager earns its place by what it can reach. MRF speaks to each robot brand the way that brand expects, reads and writes the PLCs around the robots, serves your SCADA as an OPC UA server, answers MES and ERP over a REST API, and puts the whole fleet on ISO 21423:2026, the new common language for mobile robots. This page lists every connection, its direction, and what it is for.

What talks to what.

Everything on this table ships in both site tiers, Floor and Plant, except the OPC UA server, which is on the Plant tier.

System How MRF talks to it
SystemOmron mobile robots HowARCL, the robot's own text protocol over TCP, in a session MRF keeps open per robot; REST through a gateway the site runs in front of its Omron fleet manager; and MQTT command and telemetry topics. State and telemetry in, commands out.
SystemMiR robots HowThe MiR REST API, version 2: state, telemetry and jobs, and the robot's maps and positions imported over the same API. MiR robots have no MQTT command interface, and MRF never pretends they do.
SystemOTTO robots HowThe OTTO Industrial API, version 2, over REST, plus VDA 5050 style MQTT.
SystemA robot that implements ISO 21423:2026 HowThe standard's own MQTT and JSON messages: identity, status and position in, move requests out, and the standard's request lifecycle followed back into the job.
SystemAllen Bradley PLCs HowEtherNet/IP, addressed by backplane path. Tags read on a poll; writes only to tags you mark writable.
SystemSiemens S7 PLCs HowS7 communication, addressed by rack and slot. The same read and write rules.
SystemOmron PLCs HowFINS over UDP, port 9600 by default. The same read and write rules.
SystemModbus TCP devices HowCoils and holding registers, with the same quality tracking and the same writable flag as the other PLC adapters.
SystemAny OPC UA server HowMRF as an OPC UA client: it reads the nodes you name, by node id, on each poll, from an Ignition gateway, a Kepware server, a Siemens S7-1500's own server or any gateway that exposes OPC UA.
SystemYour SCADA, historian or HMI HowMRF's own OPC UA server: every robot, every PLC tag and the count of active jobs as a browsable node tree. A write on a writable tag node is forwarded to the PLC. Plant tier.
SystemDoors, lifts, conveyors, machine tending stations and alarm panels on your PLCs HowPublished on ISO 21423 as entities of their own through MRF's PLC adapters: an identity, a status in site agreed states, and requests (open a door, call a lift, run a conveyor, start a station, acknowledge an alarm) that MRF turns into PLC writes, with the outcome read back from the tags. A device is a table row and a tag map, never a code change.
SystemMES, ERP and your own scripts HowThe REST API, and a WebSocket feed of positions, telemetry, jobs and faults, the same data the dashboard draws.
SystemThe demo fleet and PLC HowBuilt in: five simulated robots and a simulated PLC (the PLC connection is badged as simulated, and reports built on simulated data say so), for the demo and for testing your missions before a real robot moves.

Each brand, in its own language.

Omron

Three transports, all live: ARCL in a persistent session per robot, REST through a gateway the site runs in front of its Omron fleet manager, and the MQTT command and telemetry topics. A robot is dispatched through command templates you configure for it, so it is spoken to the way the brand expects.

MiR

The MiR REST API, version 2, for state, telemetry and jobs. MiR maps and MiR positions are imported over the same API, so the position names your MiR already knows become dispatch destinations in MRF.

OTTO

The OTTO Industrial API, version 2, over REST, and VDA 5050 style MQTT. OTTO sites draw the floor plan from an image you scale with two points.

An ISO 21423 robot

A robot that implements the standard publishes its identity on the bus. MRF lists it, you add it (a robot another fleet manager manages is refused), and from then on its status, position and Last Will land in the same robot model as every other brand: the live map, history, reports and the Flight Recorder show it like any robot. A map dispatch to it goes out as one move request, and the job follows the request's status.

A table, not a guess

The transports each brand can accept are a fixed table inside MRF. A robot's configuration can narrow that table, never widen it, so nobody can configure a MiR to take MQTT and then wonder why nothing moves.

One rule for the standard

A robot that joined through ISO 21423 takes the standard's request messages and nothing else. A raw MQTT command template cannot be sent to it, so nothing bypasses the protocol.

Read the line, write what you mark writable.

MRF polls each PLC connection on its own interval, keeps every tag's quality (good or bad), reconnects with backoff when a link drops, and takes a new connection from the dashboard or the API without a restart.

Allen Bradley

EtherNet/IP to the controller, addressed by its backplane path.

Siemens S7

S7 communication to the CPU, addressed by rack and slot.

Omron

FINS over UDP to the PLC, port 9600 unless your site moved it.

Modbus TCP

Coils and holding registers, with the same quality tracking and the same writable flag.

OPC UA client

Anything with an OPC UA server: an Ignition gateway, a Kepware server, a Siemens S7-1500's native server, a gateway in front of older hardware. MRF reads the nodes you name, by node id, on each poll, so a plant that already pays for Ignition or Kepware can hand MRF the tags it manages instead of running a second poll on the PLC.

The writable flag

Every tag is read only unless you mark it writable, and the server validates every write, so a tag you leave read only, a safety tag included, cannot be written from a browser. The dashboard never offers a Write button the server would refuse.

Four protocols and one base class

Allen Bradley, Siemens, Omron and Modbus TCP, each an adapter behind one base class, so a fifth protocol is a new adapter, not a rewrite.

Your SCADA sees the fleet as nodes.

MRF PLANT

The OPC UA server.

On the Plant tier MRF hosts its own OPC UA server. Any OPC UA client connects to it, browses and subscribes: Ignition, Kepware, TIA Portal, UaExpert or a script of your own. The node tree is one folder per robot (position, heading, battery, speed, status, mission and the time of its last update), one folder per PLC connection with its tags, and the count of active jobs. A write on a PLC tag node is forwarded to the PLC when that tag is marked writable, and refused when it is not.

The endpoint binds to the loopback address by default. Serving the plant network takes the bind setting, an OPC UA user name and password, and a certificate and key; on a network you trust, an explicit insecure switch can stand in for the certificate and key.

One API, the same data the dashboard shows.

REST

Robots, jobs, faults, telemetry, PLC tags, maps, trends and settings, read and written through the same API the dashboard uses.

WebSocket

A live feed of positions, telemetry, jobs and faults for the screens and systems that want to watch rather than poll.

CSV

Every trend window exports as CSV, so a costing model or a report gets measured inputs rather than a screenshot.

Fail closed

The API is protected by a key and fails closed: with no key configured it refuses requests rather than serving them, unless a developer or demo mode is switched on explicitly. Browser origins are allowlisted.

The fleet on the standard, both directions.

  1. MRF runs its own ISO 21423 session beside the vendor connections: a persistent MQTT session with a Last Will, so the bus learns when MRF drops, and an OFFLINE for every robot published before a clean stop.
  2. Every robot MRF manages appears on the bus as a standard robot: identity, status (the operating mode and state mapped from each brand's raw state) and position once a second, through a facility frame you survey from at least three reference points.
  3. MRF answers move requests addressed to it or to a robot it fronts, with the standard's full status lifecycle. A move to a point is honoured for robots MRF can drive to a coordinate: the simulated fleet today. Real Omron, MiR and OTTO robots take their jobs to named goals through their vendor commands, so for them MRF publishes and reports, and point moves over the bus follow in the next increments.
  4. Robots that implement the standard join MRF, as the Robots section above says.
  5. A reference broker configuration ships with MRF: Mosquitto, loopback only, named accounts, and an access list generator that keeps vendor traffic out of the standard's topic tree.
  6. The proof: a container test in which the open source reference implementation reads MRF's identity and a simulated robot's identity, status and position, then sends a move request that MRF walks RECEIVED, ACCEPTED, EXECUTING, SUCCEEDED.
  7. PLC controlled equipment joins the same session: each configured device is published with its identity, status and location, and serves its own requests.

Doors, lifts and machines, on the same bus as the robots.

IN THE PRODUCT

PLC equipment on the standard

Doors, lifts, conveyors, machine tending stations and alarm panels that live on a PLC, published on ISO 21423 as entities of their own, the way the standard's own worked example publishes a door: an identity, a status with site agreed states, and requests that MRF turns into PLC writes with the outcome read back from the tags. MRF's PLC adapters do the reading and the writing; the device's own interlocks stay in the PLC, MRF never writes a tag the site did not mark writable, and it refuses a request the device's state forbids (a door in fault, a lift mid travel) with the standard's reason. A device class is a table row and a tag map, not a code change.

IN THE PRODUCT

Modbus TCP

A fourth PLC adapter beside Allen Bradley, Siemens and Omron: coils and holding registers, with the same quality tracking and the same writable flag.

IN THE PRODUCT

The demo

The demo PLC carries a door, a lift, a conveyor and a machine tending station beside the simulated fleet. In the scripted scenario a robot's move request waits for the door, the door opens on the gateway's request, the robot passes, and the conveyor runs on the station's handshake.

PLANNED

Dashboard screens for the standard

Adding a discovered ISO robot and surveying the facility frame are API calls today. Both get a screen.

The lines it will not cross.

A write to a read only tag

Tags are read only unless you mark them writable, a safety tag included, and the server validates every write.

A transport a brand cannot take

The vendor table is never widened by configuration.

A raw command to a standard robot

An ISO 21423 robot takes request messages only.

A send reported that did not land

A failed dispatch is marked failed, with the reason.

Traffic arbitration

Blocking zones and right of way stay in the vendor fleet managers. MRF does not referee between robots.

Safety functions

MRF is not a safety instrumented system and must never be part of one.